Continuous monitoring of fugitive emissions
Stack Emissions Monitoring
Information
NPL have developed a system to provide long term monitoring of emissions from industrial sites. The fugitive emission detection system (FEDS) samples emissions from multiple locations around the site and measures them continuously using state-of-the-art fast response gas analyzers.
The measurements from the sampling points are combined with daily reverse dispersion modelling to locate fugitive emission locations. A probability map is generated to identify the likely source of the fugitive emissions which can be investigated.
The model then calculates the emission rates required to generate the concentrations measured. This provides reliable long-term monitoring of site emissions even if the distribution of sources changes during the measurement period. The FED system has been initially used for the monitoring of methane emissions from various sites around the UK. However, the platform approach can be adapted and widened to other emission gases through the choice of appropriate gas analyzers.